Steam sterilisation (or autoclaving) is carried out by introducing saturated water vapour under pressure. In addition to the temperature effect itself, the presence of saturated water vapour is essential for killing microorganisms, their destruction being due to irreversible denaturation of cell components. Chemical indicators for autoclaves (steam)


Chemical Indicators for Autoclaves (Steam)

Chemical indicators (CI) register as many relevant sterilisation parameters as possible, such as, for example, air expulsion and steam penetration ability, temperature, pressure and time. Chemical indicators consist of a coloured chemical compound deposited as dots on a paper strip. This chemical compound has the property that it changes colour from light blue to black when the value of the critical physical parameters for sterilisation has been attained.

Chemical indicators are a good supplement to biological indicators and must be used daily to provide rapid indication of whether the critical parameters were correct during sterilisation. However, they are no substitute for biological indicators.

Only the biological indicators can be used for measuring the efficacy of the sterilisation process.

Chemical indicators are class 5 indicators, which are produced in accordance with the requirements of the ISO 11140-1 standard.

TA typical sterilisation process using dry heat takes place at a high temperature, e.g. a minimum of 160°C for two hours. Non-For each sterilisation process, attainment of the value of the critical physical parameters, such as temperature, time, and pressure shown on the printout from the steriliser must be verified. Any deviations from the set parameters must immediately result in determination of the cause and rectification of the error.

Further, the use of chemical indicators serves to prove that the value of the critical parameters has been attained inside the items autoclaved. This means that the chemical indicators must be positioned in places regarded as challenging to sterilise.

After the sterilisation process has ended, the chemical indicators can be read immediately for correct colour occur. Only if the chemical indicator has changed completely to the final colour may the result be interpreted as evidence of attainment of the critical parameter values in the process at the place where the chemical indicator was positioned. 

Chemical Indicators can be used with different types of process challenge devices (PCDs), depending on the type of autoclave. The PDC should be replaced after 200 operating cycles.

Product range

Article numberProductPacking
83161Chemical indicator for steam + PCD
(PP/PTFE 2x3x1500 mm tube) for Class B autoclave
200 units
90242Chemical indicator for steam for Class N and Class S autoclaves200 units

Secure your process

By using biological indicators you protect your staff and patients from bacterial infections transferred from non-sterilised utensils

Get certified

We are presafe and ISO 13485 certified stated on your certificates for passed test to document your accreditation

High quality

Our indicators are of high quality. We are following the guidelines from NIR to secure the highest standard of your sterilisation process.

High service

We strive to make it as easy for you as possible. You will always have indicators in your inventory, free re-test and help to troubleshoot if needed.

If you have any questions, comments, or collaboration inquiries, you are very welcome to reach out.

Please fill in the form and we will get back to you as soon as possible.