Contact us

Home » Disease Areas » General Microbiology » Indicators » Cleaning indicators

Note: Only available in the Nordics

Cleaning indicators are used daily to test the effectiveness of the cleaning and the disinfection in washer-disinfectors used for cleaning standard instruments and instruments for minimally invasive surgery.

It is the critical parameters: time, temperature, water pressure and concentration of the detergent that are monitored. Cleaning indicators

A material consisting of artificial blood in accordance with ISO 15883 is applied to the cleaning indicator. After a cleaning cycle, the result is read manually using the included reading card. The results can be recorded on a documentation sheet on an ongoing basis.

The use of indicators is intended for everyone who needs to test cleaning processes such as hospitals, the pharmaceutical industry, the primary sector, dental surgeries and the food industry.

It is recommended that the efficacy of the cleaning process is tested for each operating cycle in order to minimise the risk of infection. This is done by placing a cleaning indicator in one of the three types of cleaning simulators – process challenge device (PCD), which simulates the penetration requirements for either hollow instruments, e.g. minimally invasive surgical (MIS) devices, equipment with small apertures or large porous loads.

Depending on the chosen PCD, this must be positioned in a representative place in the washer-disinfector or connected to a representative cleaning nozzle.

After the cleaning cycle has finished, the cleaning indicator is removed and inspected visually to ensure that there is no trace of the material on the indicator. 

Product range

The indicators are supplied in packs of 6. 

Article numberProduct
8664450-pack of cleaning indicators
866481 PCD – metal box (cleaning simulator for surgical instruments)
866465 PCD – tube (cleaning simulator for MIS instruments)
866491 PCD (PP) box – yellow (cleaning simulator for surgical instruments)
866505 PCD (PP) box – blue (cleaning simulator for narrow gaps)

Secure your process

By using biological indicators you protect your staff and patients from bacterial infections transferred from non-sterilised utensils

Get certified

We are presafe and ISO 13485 certified stated on your certificates for passed test to document your accreditation

High quality

Our indicators are of high quality. We are following the guidelines from NIR to secure the highest standard of your sterilisation process.

High service

We strive to make it as easy for you as possible. You will always have indicators in your inventory, free re-test and help to troubleshoot if needed.

If you have any questions, comments, or collaboration inquiries, you are very welcome to reach out.

Please fill in the form and we will get back to you as soon as possible.